{"product_id":"p134-gas-pressure-regulator-internal-registration-copy","title":"P133 Gas Pressure Regulator (External Registration)","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eWe stock the P133 in outlet pressures up to 10 PSIG. For outlets over 10 PSIG, or for worker monitor setups, please Contact Us to confirm availability and configure the right unit for your application.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eThe BelGAS P133 gas pressure regulator is a manual, direct-acting, spring-loaded adjustable regulator used in commercial and industrial applications where accuracy and sensitivity are critical — furnaces, burners, boilers, gas engines, and compressors. It uses a balanced diaphragm design to minimize the effects of upstream (supply) pressure changes on the downstream (output) pressure, so it holds a steady, accurate set point even as supply conditions shift. A bubble-tight shut-off means no seat-to-seat adjustment is required, and the regulator reliably operates across a temperature range of -40°F to 200°F.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eThe P133 is particularly well suited to worker monitor setups.\u003c\/strong\u003e Because it's rated for pressure monitoring service, it's a natural fit as the working monitor regulator in a monitor\/worker system — providing a second, independent stage of pressure control downstream of (or alongside) a primary regulator for added protection against overpressure events. This makes the P133 a go-to choice anywhere code or good practice calls for redundant regulation. \u003cstrong\u003eSince worker monitor configurations vary by application, contact us and we'll help you spec the right setup.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eThe P133 uses \u003cstrong\u003eexternal pressure registration\u003c\/strong\u003e — an external control line connects the outlet piping to the diaphragm chamber. This is the traditional, field-proven setup and gives installers flexibility in how and where they tap the sense line.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e If you're looking for a simpler, single-connection install without running an external sense line, we recommend the \u003cstrong\u003eBelGAS P134\u003c\/strong\u003e — a variation of the P133 platform with internal pressure registration built in. [Link to P134 product page]\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eThe P133 is one of our most popular regulators — it's a direct functional replacement for the Honeywell\/American Meter \u003cstrong\u003e3000 Series\u003c\/strong\u003e and for \u003cstrong\u003eFisher 133 \/ 133HP \/ 166\u003c\/strong\u003e regulators.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul dir=\"ltr\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eSuitable for monitoring service\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eBalanced supply valve minimizes effects of supply pressure changes\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eWide pressure range offering (17 spring ranges across L, H, and K versions)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eBubble-tight shut-off — no seat-to-seat adjustment required\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eAvailable in Ductile Cast Iron or WCB Steel body; Nitrile or Fluorocarbon trim\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eNPT or Flanged (125 FF \/ 150 RF) connections\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eRebuild kits available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul dir=\"ltr\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eIndustrial and commercial gas regulation\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eWorker\/monitor regulator setups \u003cem\u003e(contact us to configure)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eNatural gas and propane gas regulation\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFurnaces, boilers, and burners\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eGas engines\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eCompressors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eProduct Documentation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul dir=\"ltr\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\u003ca href=\"https:\/\/admin.shopify.com\/store\/mcs-meters\/content\/files\/40462055309545\" target=\"_blank\" rel=\"noopener\"\u003eP133 Spec Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eP133 Installation \u0026amp; Operation Manual (IOM)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eP133 Tech Note (Relief Valve Diagram)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch2 dir=\"ltr\" class=\"mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\" class=\"overflow-x-auto w-full px-2 mb-6 print:overflow-x-visible\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpec\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eModel \/ Series\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eP133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eType\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDirect-acting, spring-loaded, non-relieving (external registration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDiaphragm\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e14\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePort Size\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNPT or Flanged (125 FF \/ 150 RF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Inlet Pressure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e150 PSIG (varies by version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Outlet Pressure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSet + 40 PSIG (varies by version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Outlet Flow\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e170,000 SCFH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCv\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e51.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSpring Ranges\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2\" W.C. up to 60 PSIG (17 ranges across L, H, K versions) — \u003cstrong\u003ein stock up to 10 PSIG outlet; over 10 PSIG outlet available by request, contact us\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBody Material\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDuctile Cast Iron or WCB Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBonnet\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eAluminum or Cast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDiaphragm \/ Trim\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNitrile or Fluorocarbon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOrifice Material\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e-40°F to 200°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBonnet Orientation\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e12, 3, 6 (standard), or 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePort Orientation\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eUp (standard), Down, Right, Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eApplication\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCommercial, Industrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePilot Operated\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch2 dir=\"ltr\" class=\"mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eCross-Reference Part Numbers (for search + compatibility)\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eReplaces \/ Comparable to:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv dir=\"ltr\" class=\"overflow-x-auto w-full px-2 mb-6 print:overflow-x-visible\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eBrand\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eModel \/ Series\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHoneywell \/ American Meter\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003e3000 Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFisher\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003e133\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFisher\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003e133HP\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFisher\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\n\u003cstrong\u003e166\u003c\/strong\u003e (obsolete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eItron\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRB1700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eItron\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRB4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSensus\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e121-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSensus\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e121-8HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBelGAS (sister model)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eP134 (internal registration version — simpler single-connection install)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eSuggested cross-reference blurb for the listing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cblockquote class=\"ml-2 border-l-4 border-[hsl(var(--border-300)\/0.1)] pl-4 text-text-300\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eCross Reference:\u003c\/strong\u003e The P133 is a direct replacement for the Honeywell\/American Meter 3000 Series and Fisher 133, 133HP, and 166 (obsolete) regulators, as well as Itron RB1700\/RB4000 and Sensus 121-12\/121-8HP. If you're replacing any of these models, the P133 is a drop-in upgrade — and if you'd prefer to skip running an external sense line, see our \u003cstrong\u003eBelGAS P134\u003c\/strong\u003e, which uses the same platform with internal registration for an easier single-connection install.\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"BelGAS","offers":[{"title":"2 Inch NPT \/ 2\" - 4\" WC Outlet Pressure","offer_id":51628612550889,"sku":null,"price":1649.0,"currency_code":"USD","in_stock":true},{"title":"2 Inch NPT \/ 3.5\" - 6\" WC Outlet Pressure","offer_id":51628612583657,"sku":null,"price":1649.0,"currency_code":"USD","in_stock":true},{"title":"2 Inch NPT \/ 5\" - 9\" WC Outlet Pressure","offer_id":51628612616425,"sku":null,"price":1649.0,"currency_code":"USD","in_stock":true},{"title":"2 Inch NPT \/ 6\" - 14\" WC Outlet Pressure","offer_id":51628612649193,"sku":null,"price":1649.0,"currency_code":"USD","in_stock":true},{"title":"2 Inch NPT \/ 8.5\" - 18\" WC Outlet Pressure","offer_id":51628612681961,"sku":null,"price":1649.0,"currency_code":"USD","in_stock":true},{"title":"2 Inch NPT \/ 14\" - 28\" WC Outlet Pressure","offer_id":51628612714729,"sku":null,"price":1649.0,"currency_code":"USD","in_stock":true},{"title":"2 Inch NPT \/ 0.75 - 2 PSIG Outlet Pressure","offer_id":51628612747497,"sku":null,"price":1649.0,"currency_code":"USD","in_stock":true},{"title":"2 Inch NPT \/ 1.5 - 3 PSIG Outlet Pressure","offer_id":51628612780265,"sku":null,"price":1649.0,"currency_code":"USD","in_stock":true},{"title":"2 Inch NPT \/ 2 - 5 PSIG Outlet Pressure","offer_id":51628612813033,"sku":null,"price":1649.0,"currency_code":"USD","in_stock":true},{"title":"2 Inch NPT \/ 5 - 10 PSIG Outlet Pressure","offer_id":51628612845801,"sku":null,"price":1649.0,"currency_code":"USD","in_stock":true},{"title":"2 Inch Class 150 Flanged \/ 2\" - 4\" WC Outlet Pressure","offer_id":51628612878569,"sku":null,"price":2195.0,"currency_code":"USD","in_stock":false},{"title":"2 Inch Class 150 Flanged \/ 3.5\" - 6\" WC Outlet Pressure","offer_id":51628612911337,"sku":null,"price":2195.0,"currency_code":"USD","in_stock":false},{"title":"2 Inch Class 150 Flanged \/ 5\" - 9\" WC Outlet Pressure","offer_id":51628612944105,"sku":null,"price":2195.0,"currency_code":"USD","in_stock":false},{"title":"2 Inch Class 150 Flanged \/ 6\" - 14\" WC Outlet Pressure","offer_id":51628612976873,"sku":null,"price":2195.0,"currency_code":"USD","in_stock":false},{"title":"2 Inch Class 150 Flanged \/ 8.5\" - 18\" WC Outlet Pressure","offer_id":51628613009641,"sku":null,"price":2195.0,"currency_code":"USD","in_stock":false},{"title":"2 Inch Class 150 Flanged \/ 14\" - 28\" WC Outlet Pressure","offer_id":51628613042409,"sku":null,"price":2195.0,"currency_code":"USD","in_stock":false},{"title":"2 Inch Class 150 Flanged \/ 0.75 - 2 PSIG Outlet Pressure","offer_id":51628613075177,"sku":null,"price":2195.0,"currency_code":"USD","in_stock":false},{"title":"2 Inch Class 150 Flanged \/ 1.5 - 3 PSIG Outlet Pressure","offer_id":51628613107945,"sku":null,"price":2195.0,"currency_code":"USD","in_stock":false},{"title":"2 Inch Class 150 Flanged \/ 2 - 5 PSIG Outlet Pressure","offer_id":51628613140713,"sku":null,"price":2195.0,"currency_code":"USD","in_stock":false},{"title":"2 Inch Class 150 Flanged \/ 5 - 10 PSIG Outlet Pressure","offer_id":51628613173481,"sku":null,"price":2195.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/8799\/files\/P133_large_0ef05e93-fc84-433b-9d64-2e23ba15794b.webp?v=1786034141","url":"https:\/\/mcsmeters.com\/products\/p134-gas-pressure-regulator-internal-registration-copy","provider":"Measurement Control Systems","version":"1.0","type":"link"}